      Why does DigiPro2 consistently plots graphs with one extra depth when I create a profile change plot?

      Think of a measuring tape. The tape starts at zero. You don’t record the zero, but it is the origin of your length measurements. Note that the plotted value for the extra depth is always zero. If your inclinometer installation is 12m deep, and you take readings at half-meter intervals, you will take 23 readings. Your bottom reading is taken at 11.5 meters, but the origin of that interval is at 12 meters. When DigiPro draws the plot, it establishes a zero at 12 meters.

      How do I set zones for the time plot?

      Here are some instructions to get you started. A later version of the manual will document this fully.

      1. Identify the zones of interest using a change plot.
      2. Display the time plot.
      3. Right click on the plot and choose Define Zones.
      4. Enter top depth and bottom depth for as many zones as you need, then click OK.
      5. Next, right-click on the B-axis plot and choose Copy settings.
      6. Check Zones and then click OK.
      Define Zones

      How can I use the settlement correction?

      This is a two part process. The first part is entering settlement data for a particular inclinometer. The second part is applying settlement corrections to a particular inclinometer surveys.

      Entering settlement data

      1. Right click the Inclinometer. Select “Add Survey”. The survey dialog appears.

      2. Set Survey Type to “Settlement”. Enter the initial settlement survey depths. Click “OK” to save the initial settlement survey (these are depths with units in meters or feet, as appropriate).

      3. When you have new settlement data, repeat the steps above. You need a least two settlement surveys before you can apply a correction.

      Applying a settlement correction

      Now that you have settlement data in the system, DigiPro can make corrections.

      1. Click on the Inclinometer Survey to be corrected. Click “Tools”, then “Apply Settlement Correction”.

      2. The Settlement correction dialog appears. By default, the earliest and latest settlement surveys will be selected as initial and current. Click OK.

      The change (settlement or heave) between the initial and current settlement surveys will be calculated and applied to the selected Inclinometer Survey. The original survey will be left unchanged, and a new corrected Inclinometer survey will be created with the same date but with minutes and seconds set to 59:59.

       How can I enter a borehole log?

      Here are some instructions to get you started. A later version of the manual will document this fully.

      1. Select an inclinometer.
      2. Click Edit > Add/Edit Boring Log. A dialog appears.
      3. Right-click in the gray box to add a zone.
      4. Enter legend, top depth, and bottom depth in the text area below.
      5. Choose texture and color, then click X to close and choose save.
      6. Generate a plot.

      How can I export data to Atlas?

      1. Create a plot in DigiPro2. Make any corrections needed. Decide
      2. Open Plot Options in the settings panel.
      3. Double click “Use Elevations” to make it “True”. This works even if no elevations are entered.
      4. Click Export and choose a path and filename. Set file type to ” Atlas files (.dat).”
      5. Set the upload program (such as FTP Scheduler) to upload the file.
      6. Enter the inclinometer as a “sensor” in Atlas with A and B channels. Use the data file names in step 4.
      7. Create a vertical profile plot in Atlas. You must make one plot for the A and one plot for the B. You can display the two plots side by side by creating a “side by side” plot.

      How can I retrieve my templates after importing my mdb database?

      Templates were stored in a special “templates.mdb” file in the DigiPro\system folder and were not part of the normal inclinometer database file.

      1. Copy the file “c:\program files\digipro\system\templates.mdb” to your document directory.
      2. Open DigiPro2 and use the DMM database import function to import the template.mdb file.

      Why won’t my Digitilt Reader app connect?

      A1: Tap Settings > Application Manager > Digitilt Reader > Force Close. Then return to the home screen and restart the Digitilt Reader app.

      A2: Are you running the Reader app on other tablets too? One of them may be connected. To break the connection, switch off that Reel’s Bluetooth.

      Are there settings to make hands-free mode work better?

      Yes. The settings can be adjusted to the way you work and also variables at the site (such as a lot of ground vibration).

      1. Turn sound off, so you can concentrate on the action rather than the record sound.
      2. Tap Options > Survey Control.
      3. Make a change. It is best to experiment with just one change at a time rather than making lots of changes all at once.
      4. Tap “done” – the checkmark – to save the change.

      Here are some suggestions:

      • If the Reader depth is shallower than your cable depth, try setting “pull lockout” to 3 or a higher number. This tells the Reader to delay longer before accepting new input. You’ll see that the “saved” message appears for 3 seconds now. Experiment to find the right lockout timing. New users need a longer lockout, while expert users may prefer a shorter lockout.
      • If your cable depth is shallower than your Reader depth, try setting “motion” to a lower number, for example 80. Users who pull slowly need a lower number. Users who pull quickly can use a higher number.
      • If there is a lot of ground vibration at your site, you might need to use “Tap” mode, but you could try setting “motion” to a higher number and then pull quickly rather than slowly. The higher number decreases sensitivity to the ground motion, so you must accelerate the probe faster so that a pull can be detected.

      How do I obtain the Digitilt Reader app?

      Download it from the Google Play Store.

      1. Tap the Google Play icon on your Android device.
      2. Search for Digitilt Reader.
      3. Tap Install.
      4. Tap “Accept and Download” after reviewing permissions.
      5. The Digitilt Reader icon appears in your app drawer. If it does not appear on your home screen, open the app drawer to find the icon. Then tap and hold the icon. When you release, it will be placed on one of your home screens.

      How can I install the Reader app if I do not have a WIFI connection?

      Follow the steps below.

      1. Download this file to your PC: Digitilt Reader APK. (APK is an Android setup file).
      2. Connect the Android device to the PC using the USB cable supplied with the Android device.
      3. Use Windows Explorer on your PC to copy the APK file to the Android device. Any location is ok, but remember where you saved the file. After copying the file, disconnect the device.
      4. Open a File Manager program on your Android device – for example, My Files on a Samsung device.
      5. Locate the apk file and tap it. You may need to authorize the installation of applications from sources other than the Google Play Store.
      6. Now you can run the Reader app.

      What do I do if the tablet does not allow entering decimals?

      Download an alternate keyboard from the Google Play Store (such as the free Google Keyboard) that does have a decimal separator. You will need to set this as your default keyboard for your tablet.

      How can I change displayed units?

      Set default “display units” in the inclinometer settings. If you are taking readings and want to see a different unit, tap the unit label. For example, if the unit label is mm, tap the mm to toggle Digi-Metric or Digi-Native.