      How do I update the firmware for my V-Logger?

      Updating the firmware for a V-Logger is a simple process.
      1. Download and save the V-Logger firmware update here.
      2. Connect the logger to your PC via USB and run Logger Manager.
      3. Select device type “V Logger” and verify that you have the correct Comm Port selected.
      4. If needed, save all data and settings before updating the firmware.
      5. Click “Options > Firmware Update”. You should see the following warning:

      Logger firmware update

      6. Click “Upload Firmware” and navigate to the firmware update file you saved in Step 1. Select the *.bin file and press OK.
      7. The Update window will open, showing the progress of the firmware update.

      The Update window will open, showing the progress of the firmware update.

      8. When complete, the “Set Clock” window will open; it may or may not be necessary to update the clock.
      9. Confirm the firmware version by clicking “Set Up” on the Logger Manager home page. Click “Retrieve Setup”. Check the Version shown in the general settings. The current version is 2.5 A1.

      V Logger Battery Voltage

      NOTES:
      – Always update with a USB connection. Do not update firmware via a radio link.
      – The firmware update will fail if the logger starts to log a reading during the upload. If necessary, change the logging interval so that it will not interfere with the firmware update.

      If I am connecting the Gateway to my local network, are there ports that need to be open for outside communication?

      Yes. Data traffic for the Gateway must be enabled through SSH port: TCP 22.

      Does GeoFlex allow for more movement before becoming unusable?

      The GeoFlex does not allow for more movement, as both systems will perform until the signal cable  is pulled apart or cut. However, the shorter gauge lengths of the GeoFlex system do increase the reliability of the data once shearing begins. With the typical longer gauge of the IPIs, the shearing is more likely to bend the gauge rod making the displacement results questionable.

      Is the presentation of data different for GeoFlex versus IPIs?

      Presentation of the data will be exactly the same (with the exception of the higher density of readings for GeoFlex – 2 feet vs 5 or 10 feet). Both systems are plotted as displacement vs. depth. For Horizontal GeoFlex installations, data is plotted as settlement or heave versus horizontal distance rather than depth.”

      Both GeoFlex and IPIs can be installed on the same Campbell data logger. The GeoFlex uses an RS485 bus and the IPIs use an analog (RS232) bus.

      Multiple GeoFlex strings can be connected to the same Campbell data logger. The number of strings depends on the logger you are using. The CR6 and CR1000X can each handle two strings but do not require the MD-485 module as they have native RS-485 communication.

      Why should I use GeoFlex instead of a short IPI?

      The IPI sensors have the flexibility of having variable length gauge tubes. They are most typically installed with 5 or 10 feet gauge tubes, but any length can be used down to about 1.5 feet. The GeoFlex system has a 2 feet gauge length at a cost of about the same as 10 feet gauge tubes for the IPIs, thus you achieve a higher density of readings over the same distance for the same cost.

      Can the GeoFlex or IPIs be removed so that a traversing inclinometer probe can be run down the inclinometer and then the GeoFlex or IPIs placed again in casing?

      Both the IPIs and the GeoFlex systems can be removed and replaced. Please note that a new baseline will need to be set once the system has been reinstalled. Due to the lighter weight of the system, the GeoFlex is generally considered easier to remove and replace.

      Can the GeoFlex be removed at the end of a project and used on a different project?

      Yes. The standard GeoFlex segment consists of five 2 feet nodes (10 feet total) that are connected electrically via a waterproof Seacon connector and mechanically via a pinned universal joint. Once the project is complete the system can be removed and broken down into its 10 feet segments (provided that the shear isn’t so great that they can’t be removed from the casing). Those segments can be used on another project and because each node is addressable, it doesn’t matter in what order the segments are installed on the next project. The Horizontal GeoFlex uses the same durable nodes and connectors with the same redeployment benefit on future projects

      How many GeoFlex strings can I connect to a Campbell Scientific datalogger?

      Campbell Scientific (CR6 or CR1000Xe can log two strings directly; CRE350 can log two strings) It should be noted that some of these layouts may preclude the reading of other sensor types and you should contact your DGSI representative if you have a more complicated layout.

      Can readings from IPIs be compared with readings from traversing probes?

      There are many differences between the two systems that make comparisions difficult, but there is a specific instance where a valid comparison can be made.

      Readings cannot be compared directly, even if they are in the same units. Readings from both types of sensor contain an unavoidable offset. The offset is removed from traversing probe data by combining readings from two passes with opposite orientation of the sensor. The two-pass survey is not possible with IPIs, so the embedded offset value remains.

      Profile plots cannot be compared directly. Pofile plots (cumulative-deviation plots) are made by accumulating the tilt readings from each interval or sensor. The tilt of the probe or sensor is controlled by its contact with the casing. The contact points are 0.5m apart for the traversing probe, but 1m, 2m, or 3m apart for the IPI sensor. Thus the two instruments will share at most just one contact point and always report different tilt angles.

      Profile-Change Plots offer the only opportunity for comparison. These “cumulative displacement” plots are made by comparing current profile with the initial profile. The comparision removes the embedded offsets from the IPI values, but the different points of contact withing the casing are still a factor. That said, if the bottom wheels of the probe and bottom wheels of the IPI are positioned at exactly the bottom depth and the top wheels of the probe and top wheels of the IPI are positioned at exactly the same top depth, the value at the top depth should be comparable. In addition, the overall appearance od the plot should be roughly comparable.

      When can baseline readings be acquired?

      Allow the backfill around the inclinometer to stablize and wait for installation stresses to dissipate. Start recording readings right away, but choose baselines readings after readings have been stable for several days.

      Can I re-use the original baseline after I remove and replace the IPI chain?

      Probably not. If sensors are pulled from the casing and then reinstalled, the previous baseline readings are unlikely to compare well. Output will stabilize after some time passes, but even slight differences in the positioning of the sensors will appear as changes (movement) in plots. It is better to establish a new baseline.

      Are IPIs affected by vibration?

      Vibration adds noise to the output of any accelerometer-based sensor. The noise degrades the precision of the data, but the mean value of the data can still be used to show trends. Filtering and averaging could possibly improve the data.

      Strong vibrations can cause sensors to shift within the casing. The movement may be small, but the result is a change in tilt. The direction and magnitude of the shifts are random, so the resulting data values look erratic. One possible way to prevent shifting of the chain is to fill the casing with sand or soft grout.